Proportional pressure regulator valves with electronic control (will be discontinued)
Media: Oiled and unoiled compressed air, non-toxic and non-flammable gasses
Temperature range: -10°C to max. +50°C
Input signal: 0 - 10 V
Power input: 1 mA at 10 V input signal
Linearity: < 1%
Hysteresis: < 1%
Reaction sensitivity: < 0.1 %
Control time: < 1 s
Installation position: vertical ± 15°
Note: The valves get heated to an unacceptable degree if there is a signal present but the required supply pressure is missing! It is hence recommended to use a pressure switch to monitor the pressure. The input pressure should measure at least 10% higher than the maximum outlet pressure required.
Optional: Input signal 4 to 20 mA
-E20, output signal 0 to 10 V
-A10, output signal 4 to 20 mA
-A20
Catalogue page Pneumatic Atlas 7 (Page 531)
Technical documentation
All technical data are to be understood as non-binding reference values.
prices given plus VAT
Click here in order to show prices with VAT included.